Fire Door Regulations for Flats
What the law asks of freeholders, landlords and managing agents for communal and flat entrance fire doors, and what happens when faults are found.

The two laws that apply
The Regulatory Reform (Fire Safety) Order 2005 applies to the common parts of every block of flats. Under it, whoever is the responsible person has to keep fire doors and other fire safety measures maintained and in working order. The Fire Safety Act 2021 confirmed that flat entrance doors onto common parts are within its scope.
On top of that, regulation 10 of the Fire Safety (England) Regulations 2022 adds specific checks for blocks in England, with more for taller buildings.
Regulation 10 checks by building height
| Building | Communal fire doors | Flat entrance doors | Fire door information to residents |
|---|---|---|---|
| Top storey over 11m | Every 3 months | Best endeavours every 12 months | On moving in, then every year |
| Top storey 11m or under | No set interval; fire risk assessment applies | No set interval; fire risk assessment applies | On moving in, then every year |
From the government fact sheet on regulation 10. Communal doors include stair, lobby, corridor, riser and plant room doors, with their self-closers.
What counts as a fault
The fire door guidance that goes with the regulations lists the problems a check should pick up. They include:
- Gaps around the door wider than the 4mm industry standard, apart from the bottom gap.
- Intumescent strips or smoke seals that are painted over, damaged or missing.
- A self-closer that does not close the door into its frame and latch from about 15 degrees open.
- Loose or missing hinge screws, splits in the leaf, and holes left by old locks or fittings.
- Damaged glazing or beads, and missing signs on communal doors.
When faults are found
Repairs or replacements should be made by a competent contractor as soon as reasonably practicable. Not every older door needs replacing: the same guidance says a door that falls short of current Building Regulations can stay if it still works as a fire door. Our remedial works page explains how a programme is usually run.
Records and refusals
The responsible person must record the steps taken to check flat entrance doors, including refused access. Keep the dates of letters, visits and calls. A clear record of refusals protects you; a missing record suggests the checks never happened.
If the rules are ignored
Fire and rescue services enforce the Order and the 2022 regulations. Serious breaches can be prosecuted, and article 32 of the Order allows a fine with no upper limit, a prison sentence of up to two years, or both, when a failure leaves residents exposed to the risk of death or serious harm.
Who pays for the work
That depends on the lease. Communal doors are normally a service charge cost. Flat entrance doors may belong to the leaseholder or the freeholder depending on how the lease defines the demise. Our article on who pays covers the usual cases, and the cost page gives typical prices.
Fire doors in flats: common questions
Who is responsible for fire doors in a block of flats?
The responsible person for the common parts: usually the freeholder, the landlord, a right to manage company or a managing agent acting for them. Leaseholders are responsible for their own flat door only where the lease says so, and the responsible person still has to check it.
What if a resident will not allow the flat door to be checked?
The responsible person must use best endeavours and keep a record of each attempt and refusal. The gov.uk fact sheet explains what that means.
Do the 2022 regulations apply in Scotland or Wales?
No. They apply in England only. Scotland has the Fire (Scotland) Act 2005, and in Wales the Fire Safety Order applies without the regulation 10 checks.
Thanks. Your building is on our list.
What follows:
- One door firm is chosen for the postcode, and its name comes to you by email.
- You answer yes or no. Without a yes, nothing is passed on.
- The firm gets in touch for the survey report or a visit, and prices the doors in writing.
Need the block's doors put right?
Four details and you are done. Have your fire door survey or inspection report to hand: the firm will want it when they call, because it lets them price the work door by door.
We find a fire door firm working near the building and name that firm to you before a single detail of yours is shared. You pay nothing for this.