Fire Door Upgrades and Replacements
When a door is past repair, or was never a fire door at all, the answer is a certified doorset fitted to its instructions.

Repair or replace?
Repair is the default. The government fire door guidance is clear that a working fire door does not need replacing just because it is older than the current rules. Replacement makes sense when:
- The leaf or frame is split, rotten or badly damaged.
- There is no label, certificate or evidence that the door was ever fire rated.
- Past alterations, such as cat flaps or non-rated glazing, have gone too far to put right.
- The cost of repairing several faults on one door comes close to the price of a new one.
Why a certified doorset
A doorset is the leaf, frame, seals, glass and ironmongery supplied and tested together. Fitting one, rather than a leaf hung in an old frame, gives you evidence for every part. Look for third-party certification marks on the leaf and frame, and keep the certificate with the building records.
Flat entrance doors in blocks usually need a smoke seal and a self-closer as well as fire resistance, and many councils now fit only certified doorsets to them. Hounslow Council's programme is one public example.
Taller buildings and building control
Replacing a fire door is building work. In higher-risk buildings, at least 18m or seven storeys with two or more homes, changes go through the Building Safety Regulator. In lower buildings a Competent Person Scheme installer can sign off the work. Approved Document B sets the fire performance the new door must meet.
What to ask a fitter
- Which certification scheme covers your installation work?
- Will the doorset be fitted to the manufacturer's instructions, including the gap around the frame?
- What label, certificate and photos will we get for each door?
- Who deals with building control or the regulator?
For prices by door type, see the fire door replacement cost page. If most doors just need repairs, start with remedial works instead.
Rules that apply to replacements
Which law: Replacement is building work under the Building Regulations. (Approved Document B)
When: Where a door cannot be repaired to work as a fire door. (gov.uk fire door guidance)
Ask for: Doorset certificate, label reference and completion photos. (BS 8214 code of practice)
Flats over 11m: New doors then checked under regulation 10. (legislation.gov.uk)
Upgrade and replacement questions
Can an ordinary door be upgraded to a fire door?
Rarely in a way that holds up. Upgrade kits and coatings exist, but a door that was never fire rated has no test evidence to repair back to. A certified doorset is usually the safer and simpler route.
Do replacement fire doors need building control approval?
Replacing a fire door counts as building work. In higher-risk buildings it goes through the Building Safety Regulator, and in homes a Competent Person Scheme installer can self-certify. Approved Document B sets the performance needed.
What is the difference between FD30 and FD60?
The number is the minutes of fire resistance the door was tested to: 30 or 60. An S after it, as in FD30S, means it also resists the passage of smoke.
Thanks. Your building is on our list.
What follows:
- One door firm is chosen for the postcode, and its name comes to you by email.
- You answer yes or no. Without a yes, nothing is passed on.
- The firm gets in touch for the survey report or a visit, and prices the doors in writing.
Get prices for new fire doors
Four details and you are done. Have your fire door survey or inspection report to hand: the firm will want it when they call, because it lets them price the work door by door.